Gammasphere LN status/alarm system

dgs1: @ Thu Sep 29 14:37:36 2022

VXI crate6 is up

LN: detector filling: idle
LN: tank filling....: idle

last fill: ??:?? ?????
next fill: 17:01 Sep27
time since last fill:
last fill took:
number of alarms: 0
last tank fill: ??:?? ?????
last tank fill took:

--list of monitored detectors:
ge 008 _on 0000V T[K]: [ 85.0 - 105.0] 88.7 {-16.3}
ge 011 _on 0000V T[K]: [ 80.0 - 100.0] 88.9 {-11.1}
ge 013 _on 0000V T[K]: [ 85.0 - 105.0] 95.1 { -9.9}
ge 014 _on 0000V T[K]: [ 85.0 - 105.0] 96.1 { -8.9}
ge 015 _on 0000V T[K]: [ 90.0 - 110.0] 101.3 { -8.7}
ge 017 _on 0000V T[K]: [ 85.0 - 105.0] 95.6 { -9.4}
ge 018 _on 0000V T[K]: [ 85.0 - 105.0] 94.6 {-10.4}
ge 019 _on 0000V T[K]: [ 75.0 - 95.0] 88.2 { -6.8}
ge 020 _on 0000V T[K]: [ 75.0 - 95.0] 83.7 {-11.3}
ge 021 _on 0000V T[K]: [ 80.0 - 100.0] 89.5 {-10.5}
ge 022 _on 0000V T[K]: [ 85.0 - 105.0] 96.6 { -8.4}
ge 023 _on 0000V T[K]: [ 75.0 - 95.0] 81.2 {-13.8}
ge 024 _on 0000V T[K]: [ 85.0 - 105.0] 98.6 { -6.4}
ge 025 _on 0000V T[K]: [ 80.0 - 100.0] 93.0 { -7.0}
ge 026 _on 0000V T[K]: [ 85.0 - 105.0] 99.2 { -5.8}
ge 027 _on 0000V T[K]: [ 85.0 - 105.0] 106.4 { 1.4} WARM, hose: H2-26 ****
ge 028 _on 0000V T[K]: [ 85.0 - 105.0] 92.8 {-12.2}
ge 029 _on 0000V T[K]: [ 75.0 - 95.0] 91.2 { -3.8}
ge 030 _on 0000V T[K]: [ 85.0 - 105.0] 97.2 { -7.8}
ge 031 _on 0000V T[K]: [ 85.0 - 105.0] 96.4 { -8.6}
ge 032 _on 0000V T[K]: [ 85.0 - 105.0] 96.6 { -8.4}
ge 033 _on 0000V T[K]: [ 85.0 - 105.0] 93.6 {-11.4}
ge 034 _on 0000V T[K]: [ 85.0 - 105.0] 95.1 { -9.9}
ge 035 _on 0000V T[K]: [ 85.0 - 105.0] 97.2 { -7.8}
ge 036 _on 0000V T[K]: [ 85.0 - 105.0] 95.1 { -9.9}
ge 037 _on 0000V T[K]: [ 85.0 - 105.0] 99.2 { -5.8}
ge 039 _on 0000V T[K]: [ 85.0 - 105.0] 93.6 {-11.4}
ge 041 _on 0000V T[K]: [ 85.0 - 105.0] 94.8 {-10.2}
ge 042 _on 0000V T[K]: [ 85.0 - 105.0] 99.2 { -5.8}
ge 044 _on 0000V T[K]: [ 85.0 - 105.0] 96.0 { -9.0}
ge 047 _on 0000V T[K]: [ 85.0 - 105.0] 94.1 {-10.9}
ge 048 _on 0000V T[K]: [ 85.0 - 105.0] 95.6 { -9.4}
ge 063 _on 0000V T[K]: [ 85.0 - 105.0] 97.2 { -7.8}
ge 067 _on 0000V T[K]: [ 80.0 - 100.0] 88.9 {-11.1}
ge 069 _on 0000V T[K]: [ 85.0 - 105.0] 97.2 { -7.8}
ge 071 _on 0000V T[K]: [ 85.0 - 105.0] 99.2 { -5.8}
ge 075 _on 0000V T[K]: [ 85.0 - 105.0] 95.1 { -9.9}
ge 077 _on 0000V T[K]: [ 85.0 - 105.0] 94.6 {-10.4}
ge 079 _on 0000V T[K]: [ 85.0 - 105.0] 96.1 { -8.9}
ge 081 _on 0000V T[K]: [ 85.0 - 105.0] 95.4 { -9.6}
ge 082 _on 3896V T[K]: [ 79.0 - 99.0] 90.0 { -9.0}
ge 083 _on 0000V T[K]: [ 75.0 - 95.0] 82.9 {-12.1}
ge 084 _on 3499V T[K]: [ 78.0 - 98.0] 87.7 {-10.3}
ge 085 _on 0000V T[K]: [ 90.0 - 110.0] 100.5 { -9.5}
ge 086 _on 3969V T[K]: [ 79.0 - 99.0] 88.5 {-10.5}
ge 087 _on 0000V T[K]: [ 85.0 - 105.0] 97.5 { -7.5}
ge 088 _on 3693V T[K]: [ 71.0 - 91.0] 83.1 { -7.9}
ge 089 _on 0000V T[K]: [ 85.0 - 105.0] 95.1 { -9.9}
ge 090 _on 3293V T[K]: [ 70.0 - 90.0] 75.0 {-15.0}
ge 091 _on 0000V T[K]: [ 75.0 - 95.0] 82.3 {-12.7}
ge 092 _on 2997V T[K]: [ 79.0 - 99.0] 87.0 {-12.0}
ge 093 _on 0000V T[K]: [ 80.0 - 100.0] 88.9 {-11.1}
ge 094 _on 4018V T[K]: [ 68.0 - 88.0] 83.7 { -4.3}
ge 095 _on 0000V T[K]: [ 85.0 - 105.0] 96.1 { -8.9}
ge 096 _on 4194V T[K]: [ 75.0 - 95.0] 88.2 { -6.8}
ge 097 _on 0000V T[K]: [ 75.0 - 95.0] 83.3 {-11.7}
ge 098 _on 3015V T[K]: [ 68.0 - 88.0] 77.3 {-10.7}
ge 099 _on 0000V T[K]: [ 75.0 - 95.0] 83.8 {-11.2}
ge 100 _on 2496V T[K]: [ 78.0 - 98.0] 84.0 {-14.0}
ge 101 _on 0000V T[K]: [ 75.0 - 95.0] 89.1 { -5.9}
ge 102 _on 4028V T[K]: [ 65.0 - 85.0] 79.4 { -5.6}
ge 103 _on 0000V T[K]: [ 75.0 - 95.0] 91.8 { -3.2}
ge 104 _on 3512V T[K]: [ 78.0 - 98.0] 88.5 { -9.5}
ge 105 _on 0000V T[K]: [ 75.0 - 95.0] 86.9 { -8.1}
ge 106 _on 3993V T[K]: [ 66.0 - 86.0] 78.2 { -7.8}
ge 107 _on 0000V T[K]: [ 75.0 - 95.0] 86.9 { -8.1}
ge 108 _on 4004V T[K]: [ 69.0 - 89.0] 79.0 {-10.0}
ge 110 _on 3512V T[K]: [ 71.0 - 91.0] 84.2 { -6.8}

a total of 68 detectors are monitored